Medical device registries are central to identifying and studying device outcomes. They support short- and long-term surveillance as well as comparative safety and effectiveness assessments. Their value lies in bridging the gap between device performance in clinical trials and real-world use over time.
This guide is for clinicians, clinical affairs teams and evidence leads who are deciding whether to join, buy or build a registry, and who need it to stand up to regulators, health technology assessment (HTA) bodies and the clinicians who enter the data. It covers the types of registry, what each audience asks of the data, and how to design one that is credible.
In short
- Definition: A medical device registry systematically collects clinical and patient data on devices in routine use. A post-market registry does this after market authorisation, to follow safety and performance over time.
- Why it matters: One well-designed dataset can serve four audiences: the notified body, the FDA, HTA bodies and payers, and clinicians.
- Choice: You can join an existing registry, buy real-world data or build a sponsored registry. Whichever you choose, the manufacturer remains responsible for the quality of the evidence.
- Design test: Write the evidence questions first, then the fields. Decide the level of regulatory-grade control before go-live, not after.
What is a medical device registry?
A medical device registry is an organised system that collects real-world data on patients treated with specific devices. A post-market registry is the type manufacturers run after a device is on the market, to confirm safety and performance over time and to generate evidence for regulators, payers and clinicians. It does a different job from a post-market clinical follow-up (PMCF) plan. The PMCF plan says what you will collect. The registry is where several years of that data actually live.
For the regulatory detail on PMCF and post-market surveillance (PMS), read these Academy articles:
- Post-market clinical follow-up (PMCF): what activities are there?
- Medical device post-market surveillance: the complete guide
Not what you are looking for? Registering a device with the MHRA, or in the EU database, is regulatory registration. It is not a clinical registry. Trial registries such as ISRCTN and ClinicalTrials.gov record that a study exists and how it is designed. They do not collect patient outcome data over time.
Four ways to collect post-market data
| Route | Who runs it | Control over dataset | Cost | Regulatory weight | Typical use |
|---|---|---|---|---|---|
| National device registry | Health system, commissioner or professional society | Low: the registry owner sets the dataset | Low for the manufacturer | High where the registry is independent and captures the device at product level | Long-term implant performance across a country |
| Manufacturer-sponsored registry | Manufacturer, often with clinical or academic partners | High: you define endpoints and follow-up | Highest | Depends on design and governance | Product-specific evidence, new indications, HTA |
| PMCF study | Manufacturer, to a protocol | High, but fixed to the protocol question | Medium to high | High if well designed | Closing specific evidence gaps |
| Other real-world data (EHR, claims) | Third parties | Low | Variable | Depends on relevance and reliability | Large-scale outcomes, comparators |
One dataset, four audiences
A registry that is designed for one audience tends to disappoint the others. Plan for all four at the start, so you run one data collection and not four.
- Notified body: Asks whether the evidence confirms safety, performance and an acceptable benefit-risk balance, and whether it closes the gaps in the clinical evaluation.
- The US Food and Drug Administration (FDA): Asks whether the data is relevant to the regulatory question and reliable enough to count as valid scientific evidence.
- HTA bodies and payers: Ask how outcomes compare with current care, and what the device costs or saves.
- Clinicians: Ask whether the device works for their patients, and whether they can see their own results.
Under the EU MDR, PMCF is a continuous part of post-market surveillance, and evaluating suitable registers is a recognised PMCF method. The detail sits in our guides: the PMCF guide covers Annex XIV Part B and the MDCG plan and report templates, and the PMS guide covers PSURs and the Great Britain Part 4A requirements.
Join, buy or build?
There are three routes. Most manufacturers end up combining them.
| Route | Pro | Con | When to use |
|---|---|---|---|
| Join an existing national registry | Credible and independent | Limited control over dataset and access, and product-level granularity is not always available | The registry already captures your device type and your endpoints, and its owner will share data |
| Buy real-world data | Fast | Quality and fitness for purpose are the manufacturer's responsibility; treat data vendors as critical suppliers | You need a comparator or large-scale context quickly, and you can audit the source |
| Build a sponsored registry | Full control over endpoints, follow-up and data quality | Higher cost and effort; must manage perceived bias through independent governance | No existing source answers your questions, or you need data across several countries and indications |
UK, EU and US: what each regulator will accept from registry data
United Kingdom
Since 16 June 2025, Great Britain has had its own post-market surveillance rules (SI 2024/1368, which adds Part 4A to the UK Medical Devices Regulations 2002). Every manufacturer must run a documented PMS plan that actively collects and analyses real-world data, and higher-risk devices need regular safety update reports. Registry data counts as a source. Many devices still reach the GB market with a CE mark, and on 21 October 2026 the government confirmed that CE marked devices will be accepted in Great Britain indefinitely (read our analysis of the announcement). Evidence built for EU PMCF therefore often serves the UK as well.
National registries and audits, such as the National Joint Registry and the HQIP-commissioned clinical audits, are the comparators UK clinicians and NICE look to. The MHRA and NICE also run a joint real-world evidence scientific dialogue, which now accepts devices.
European Union
Under the MDR, registries are a named method for post-market clinical follow-up (PMCF, Annex XIV Part B). MDCG 2020-6, written for legacy devices but widely used as a reference, ranks data from high-quality registries at level 3, above most observational studies. Legacy Class III and implantable devices need level 4 or better.
Notified bodies don't accept registry data just because it exists. They look for:
- A plan written before data collection starts
- Endpoints and acceptance criteria tied to the device's claimed benefits
- A justified sample size
- Device-level identification (UDI)
- Complete follow-up
Joining a national registry is not enough on its own. The manufacturer must show the data is relevant to its device and reliable. The December 2025 proposal to revise the MDR would widen the types of data accepted, but it is still a proposal, not law.
United States
The US Food and Drug Administration (FDA) finalised its real-world evidence guidance for devices in December 2025, replacing the 2017 version. Registry data can support new clearances and approvals, label expansions, post-approval studies and Section 522 surveillance studies.
The FDA judges data on two tests: relevance (does it answer the question?) and reliability (how was it collected and quality-controlled?). The protocol and analysis plan should be finalised before anyone looks at outcome data. The registry should also be able to give the FDA access to patient-level data and audit trails, so electronic records that meet 21 CFR Part 11 matter here.
HTA and payers
Regulatory approval doesn't guarantee reimbursement. Payers ask a different question: is the device better value than what it replaces? That means comparative outcomes, patient-reported outcomes and resource use. NICE uses real-world evidence but generally expects it to be published. EU joint clinical assessments of high-risk devices began in 2026 under the HTA Regulation (EU) 2021/2282. National bodies still often ask for further studies after a device is listed for reimbursement.
In the US, Medicare's Transitional Coverage for Emerging Technologies (TCET) pathway links coverage to ongoing evidence generation for certain breakthrough devices. The practical point is to design the registry once, for the strictest reader, and reuse the same dataset for the Clinical Evaluation Report (CER), PSUR, FDA and HTA.
Designing a registry regulators and clinicians will trust
Start from the evidence questions, not the fields
Build on the insights you already have in your clinical evaluation plan, your PMCF plan and the HTA questions, which cover population, intervention, comparator and outcome. Map each question to an endpoint. If a field does not serve a question, leave it out.
Use a common core plus modules
If the device is used across several procedures or indications, one shared core dataset with procedure-specific modules keeps the workload for sites consistent and avoids running many separate studies. It also makes it easier to add the next indication.
Decide the level of control before you go live
If registry data may support an FDA decision, it may need trial-grade controls such as an audit trail, electronic signatures, source verification and monitoring. Where relevant, consider alignment with 21 CFR Part 11 and ISO 14155. Retrofitting these is much harder than starting with them.
Pre-specify signals and thresholds
Agree in advance what rate or pattern triggers a review of the risk management file and the clinical evaluation report. Signals defined after the data arrive are hard to defend, which is why pre-defined safety thresholds are valuable.
Set up independent governance
A steering committee that includes clinicians, a publication policy and clear data access rules help address the concern that manufacturer-sponsored data are biased.
Include patient-reported outcomes where patient benefit matters to payers
Choose the instruments, the timing and the way patients complete them at the start. Some instruments require a licence.
For AI-based software devices
Consider capturing the data you need to monitor performance drift and bias in real-world use.
The hard parts
- Site participation: You cannot mandate it. Engagement fades unless entry is quick and sites see their own data. Ask only for what routine data cannot provide.
- Data quality: Poor data entered at the start cannot be repaired later. Validation at entry, completeness checks and monitoring are cheaper than cleaning afterwards.
- Regulatory-grade controls: Trial-like controls are hard to scale across many sites. Decide where you need them.
- Multi-country governance: GDPR, ethics approvals, contracts and data transfers differ by country, and the approvals take time. Start early.
- Device identification and attrition: Linking a device identifier (UDI) to a patient outcome over many years requires the identifier to be recorded at the time of implantation or use, and a plan for patients lost to follow-up.
Checklist: before you launch a post-market registry
- Evidence questions mapped to MDR, FDA and HTA needs
- Join, buy or build decision documented
- Core dataset plus modules defined
- Relevance and reliability documentation in place
- Validated platform with audit trail
- Signal thresholds linked to risk management and the CER
- Site engagement and feedback plan
- Independent governance and publication policy
- Multi-country data protection and ethics approvals
- Long-term follow-up and retention plan
How Ledidi supports post-market registries
The centre of gravity in MedTech evidence is moving from pre-market to post-market. The EU MDR makes post-market clinical follow-up continuous, the FDA has widened the door for real-world evidence, and HTA bodies want comparative real-world outcomes.
So a post-market registry is no longer a compliance cost. It is the asset behind indication expansion, reimbursement and adoption. Design it once for four audiences: the notified body, the FDA, HTA bodies and payers, and the clinicians who use the device.
Ledidi Registries and Ledidi Trials run on one secure platform, so data can move from study to registry without migration. Ledidi Trials was independently audited and confirmed audit-ready in January 2026 against FDA 21 CFR Part 11, ICH GCP E6 (R3) and ISPE GAMP 5. The platform is ISO 27001, SOC 2 Type II and GDPR compliant, with data hosted in AWS EU regions.
Building your PMCF or RWE plan? Talk to us about designing a registry once for every audience. Book a demo
Read more from Ledidi Academy
- What is a clinical registry? Why clinicians build them and how to make them last
- Post-market clinical follow-up (PMCF): what activities are there?
- Medical device post-market surveillance: the complete guide
- The UK just made CE marking indefinite. Here's what it doesn't change.
Frequently asked questions
Does the FDA accept registry data as RWE?
Yes. FDA guidance on real-world evidence for devices, finalised in December 2025, names registries as a source of real-world data. Registry data has supported new clearances and approvals, label expansions and post-approval studies, and the FDA publishes examples of authorisations that used it.
Being a registry doesn't earn acceptance on its own. The FDA judges each dataset on relevance (does it capture the right patients, device and outcomes?) and reliability (how was the data collected, checked and audited?). Agree the protocol and analysis plan before you look at outcomes, and talk to the FDA early through the Q-Submission programme.
Can a national registry satisfy PMCF?
Sometimes, and rarely on its own. Under the EU MDR, registries are a recognised PMCF method, and MDCG 2020-6 places high-quality registry data above most observational studies. But the notified body will ask whether the registry answers your device's open clinical questions.
Can it identify your device and model, not just the device type? Does it record the endpoints and follow-up your PMCF plan needs? Can you get timely access to the data? Many national registries record only device type or a narrow set of outcomes, so manufacturers often combine registry data with their own targeted data collection. Justify the choice in the PMCF plan either way.
How long should follow-up last?
No regulation sets a fixed duration. Follow-up should cover the device's expected lifetime and the timeframe over which its benefits and risks appear. Implants, especially orthopaedic and cardiovascular ones, typically need follow-up of several years to over a decade. Short-term-use devices may need months.
Notified bodies and the FDA look for a duration justified by the clinical question and the risk profile, plus a plan to keep patients from being lost to follow-up. Linking to routine health records, such as hospital episode statistics or mortality data, can extend follow-up without extra visits.
Who owns the data?
“Ownership” is the wrong frame under GDPR and UK GDPR. Patients don't own their data, but they have rights over it, such as access and objection. The organisation that decides why and how data is collected is the data controller. For a hospital or society registry, that is usually the hospital or registry holder. For commissioned national audits in England, it is the commissioning body. A manufacturer-sponsored registry is usually controlled by the manufacturer, with hospitals as data sources.
The software provider is normally a processor acting on the controller's instructions. Manufacturers that use someone else's registry need a data-sharing agreement setting out access, purpose and publication rights. Agree this before launch, because it is much harder to settle afterwards.
Sources
- Agency for Healthcare Research and Quality: Registries for Medical Devices, in Registries for Evaluating Patient Outcomes
- Department of Health and Social Care: Independent Medicines and Medical Devices Safety Review: update report on government implementation
- Department of Health and Social Care: The medical technology strategy: one year on
- European Commission: Regulation (EU) 2017/745, Medical Device Regulation
- FDA: Use of Real-World Evidence to Support Regulatory Decision-Making for Medical Devices